Product : Cisco, HyperFlex [HCI]/4.0, x86
Feature : Flash Capacity, Flash, Storage Support
Content Owner:  Herman Rutten
Summary
Hybrid: 2 Flash devices per node (1x Cache; 1x Housekeeping)
All-Flash: 9-26 Flash devices per node (1x Cache; 1x System, 1x Boot; 6-23x Data)
All-NVMe: 8-11 NVMe devices per node (1x Cache, 1x System, 6-8 Data)
Details
In Cisco HyperFlex hybrid configurations each storage node has 2 or 3 SSDs.

HX220c / HX220x Edge:
1 x 240GB SSD for boot
1 x 240GB SSD for system
1 x 480GB/800GB SSD for caching

HX240c:
1 x 240GB SSD for boot
1 x 240GB SSD for system
1 x 1.6TB SSD for caching

Fully Distributed Read Cache: All SSD caching drives within the HyperFlex storage cluster form one big caching resource pool. This means that all storage nodes can access the entire distributed caching layer to read data.

In Cisco HyperFlex all-flash configurations each storage node has 8-26 SSDs.

HXAF220x Edge:
1 x 240GB SSD for boot
1 x 240GB SSD for system/log
1 x 400GB/1.6TB SSD for caching
6-8 x 960GB/3.8TB SSD for data

HXAF220c:
1 x 240GB SSD for boot
1 x 240GB SSD for system/log
1 x 375GB Optane/400GB/800GB/1.6TB SSD for caching
6-8 x 800GB/960GB/3.8TB SSD for data

HXAF240c:
1x 240GB SSD for boot
1x 240GB for system/log
1x 375GB Optane/400GB/800GB/1.6TB SSD for caching
6-23 x 800GB/960GB/3.8TB SSD for data